6kVA HZAQ-KS Glove Tester Control Desk
Overview
The complete set of testing equipment is based on the HZAQ-KS Intelligent console, HZQ-6/60 AC Hipot Tester, and divider. It is equipped with HZAQ-YW Insulated boots glove leakage current test bench, HZAQ-YWB Insulated boots glove leakage current test benchh and other equipment to complete a number of testing works.
Main technical data
Rated output voltage: 60KV (insulating boots, insulating gloves test)
Rated capacity: 6KVA
Output voltage range: 60.0KV (250V)
Voltage measurement error: < ± (1.0% U+0.1%Umax)
Where U is the indicated value, Umax is the upper limit of the range
Input current range: 30.0A
Current measurement error: < ± (0.5%I+0.05%Imax),
Where I is the indicated value, Imax is the upper limit of the range
Divider:
Voltage divider ratio: 990:1
Voltage divider ratio error: 1.5%
HZAQ-YW Insulation Glove Test Bench:
Test position: 6
Leakage current range: 25.0mA
Leakage current measurement error: ± (1.0%I+0.1 words)
Leakage current resolution: 0.01 mA
HZAQ-YWB Insulation Glove Test Stand:
Test position: 8
Leakage current range: 25.0mA
Leakage current measurement error: ± (1.0%I+0.1 words)
Leakage current resolution: 0.01 mA
Test items, periods and requirements of auxiliary insulating boots (shoes) (DL/T1476-2015) | |||||
project | cycle | Voltage grade (kV) | Test Voltage (KV) | Duration (min) | Leakage current (mA) |
Power frequency withstand voltage test | Half a year | The low pressure | 2.5 | 1 | ≦ 2.5 |
High pressure | 8 | 1 | ≦ 9 | ||
Electrical characteristics of insulating gloves (DL/T976-2005) | GB 17622-2008 | ||
model | Rated voltage (V) | AC withstand voltage (effective value) (V) | Water depth |
1 | 3000 | 10000 | 40 |
2 | 10000 | 20000 | 90 |
3 | 20000 | 30000 | 130 |
Equipment maintenance and maintenance
Please read this manual carefully before use.
The insulating boots and gloves test bench tests the built-in battery of the host machine. When the battery power is low, the battery shall be charged in time;The battery shall be charged once every 1 to 2 months during the long-term storage period of 8.3.
The surface of the test table and the high-voltage electrode plate of the insulation pad tester should be smooth to avoid injury.
All the insulation parts of the equipment should be protected from moisture and should not be soaked in water. If there are stains, wipe them with a wet cloth and dry them thoroughly before use.
If the ambient temperature of the equipment is lower than 0℃, please completely drain the water in the waterway and store it, so as to avoid the damage of equipment parts caused by icing.
If you are satisfied with this instrument, please tell your colleagues; if you are dissatisfied with this instrument, please call (0312) 6775656 and tell us-Baoding Huazheng Electric Manufacturing Co., Ltd., our company will definitely satisfy you!
Huazheng Electric Manufacturing (Baoding) Co., Ltd
Contact: Julia
Department: Sales Manager
: sales09
Tel: +86-312-6775511
Fax: +86-312-6775656
Mob/Whatsapp:0086-
Skype:juliajin-huazheng
Address: Electeicity Valley Tech Centre, No.3088 Lekai Street, Hi-tech Zone, Baoding , Hebei , China.
Zip: 071000
After-sales service
The product will be maintained free of charge within one year from the date of sale.If the damage is not due to the normal operation of the instrument, the cost shall be charged.
After the warranty period, maintenance for life will be charged at cost only.
The built-in battery of all instruments is not covered by the warrant
















所有评论仅代表网友意见,与本站立场无关。