产品简介

Automatic Open Flash Point Tester Overview 1. Product Name: Automatic open flash point tester 2. Instrument model: hzks-n3 3. Component control switch and button: cooling fan, ignition, mechanism lifting and fire sweeping once 4. Interface switch button: system setting, method setting, historical data, equipment detection,...

详情介绍

HZKS-N3 Oil Open Cup Flash Point Meter

Overview

1. Product Name: automatic open flash point tester

2. Instrument model: hzks-n3

3. Component control switch and button: cooling fan, ignition, mechanism lifting and fire sweeping once

4. Interface switch button: system setting, method setting, historical data, equipment detection, instrument calibration, commissioning and analysis interface

5. Sample related parameters: sample temperature and hot bath temperature

6. Atmospheric pressure and temperature in the cabinet

HZKS-N3 open cup flash point analyzer

HZKS-N3  hzksn3 flash point apparatus

HZKS-N3_05

HZKS-N3_04

HZKS-N3_03

Tech Data

Applicable standards: gb/t 3536-2008, gb/t 267-88 and other standards

Working power supply: AC220V 10% 50Hz

Heating power: 600W (standby)

Overall power: maximum 750W

Ambient temperature: 5-40 ° C

Overall dimension: 380x360x360mm

Weight of main engine: About kg

Range: room temperature ~ 400 ℃

Resolution: 0.1 ℃

Repeatability: ≤ 4 ℃


Preparation

1.Clean

Before each experiment, clean the cup.

2.Sample preparation

Shake the sample before the experiment.

Pour the sample into the scale line of the test cup, and there are two graduation lines. Select the scale line according to the sample.

3.Start experiment

Set the method parameters for the experiment in the method setting interface, save and exit.

Select the method for this experiment in the analysis interface.

Enter the number of the test sample in the analysis interface.

Wait for the bath temperature to reach the temperature set in the method.

Put the sample cup in the heating bath.

Click the analysis interface button to enter the analysis interface.

Click the experiment stopped switch in the analysis interface to change the switch text into experiment started and experiment test started.

After the experiment is started, the instrument controls the whole experiment process according to the parameters set by the method, and the user monitoring is not required.

After the experiment, the hot bath fan is turned on, so that the hot bath can quickly return to the method to set the cooling temperature value.

4.End of experiment

At the end of the experiment, please clean the cup for the next experiment.

Wait for the temperature of the hot bath to fall within the safe temperature range and turn off the power.

Wipe the flash point detector gently with clean paper or cloth.

onsite testing

Huazheng Electric Inquiry_

上一篇: HZFJ80 SF6 Gas Discharge Decompositi
下一篇: HZMD20 Automatic SF6 Gas Density Rel
同类优质产品

在线询价

X

已经是会员?点击这里 [登录] 直接获取联系方式

会员登录

X

请输入账号

请输入密码

=

请输验证码

收藏该商铺

X
该信息已收藏!
标签:
保存成功

(空格分隔,最多3个,单个标签最多10个字符)

常用:

提示

X
您的留言已提交成功!我们将在第一时间回复您~