当前位置:Huazheng Electric Manufacturing (Baoding) Co., Ltd>>Partial Discharge Tester>> HZ-9003C Fully Functional Ultratev Partial Discharge Detection Equipment

HZ-9003C Fully Functional Ultratev Partial Discharge Detection Equipment

产品二维码
参  考  价:面议
具体成交价以合同协议为准
  • 产品型号:
  • 品牌:
  • 产品类别:磨床
  • 所在地:
  • 信息完整度:
  • 样本:
  • 更新时间:2026-03-21 10:06:45
  • 浏览次数:
收藏
举报

联系我时,请告知来自 亚洲制造网

Huazheng Electric Manufacturing (Baoding) Co., Ltd

其他

  • 经营模式:其他
  • 商铺产品:831条
  • 所在地区:
  • 注册时间:2026-03-20
  • 最近登录:2026-03-20
  • 联系人:Julia
  • 电    话:
产品简介

HZ-9003C Fully Functional Ultratev Partial Discharge Detection Equipment I.Standards The portable partial discharge tester is designed per the following standards: GB/T 7354-2003 Partial discharge measurement GB 4793.1-2007 Safety requirement for electric equipment for measurement, control, and...

详情介绍

HZ-9003C Fully Functional Ultratev Partial Discharge Detection Equipment

I.Standards

The portable partial discharge tester is designed per the following standards:

GB/T 7354-2003 Partial discharge measurement

GB 4793.1-2007 Safety requirement for electric equipment for measurement, control, and laboratory use- Part 1: General requirements,

GB/T 2423.8-1995 Environmental testing for electric and electronic products,

GB 2900 Electrotechnical terminology

GB/T 16927 High voltage testing techniques

DL/T 356-2010 Calibration specification of partial discharge measuring devices

DL/T 417-2006 Guide for Partial Discharge Measuring of Power Equipment

IEC1000 Electromagnetic compatibility

II.Operation Notice

1.Read the manual carefully before operating the measuring device.

2.When use different sensors for measurement during the testing, should setup correct parameters at the “ parameter settings" to ensure the measurement accuracy.

3.If needs to replace sensors during the testing, should turn off the “ output voltage".

4.During the testing, should handle the device with care, to avoid any bumps.

5.After testing, please turn off the power and then charge the device.

III.General

Portable PD tester is used for on-line detection and location of partial discharge of HV equipment, which is designed based on our many years experiences in the partial discharge measuring fields.

The system is equipped with composite TEV sensors, ultrahigh frequency sensors, High-frequency current transformers and high sensitivity ultrasonic sensors to collect partial discharge signals at high voltage equipment. The system adopts multilevel detect frequency reduction techniques to reduce the discharge frequency of the signals, meantime using high-speed AD conversion circuit to complete the signal digitization, also by using digital signal processing, adaptive filtering interference signal processing methods to ensure the reliability of the testing data. By collecting different signals produced from the partial discharge in different high equipment, the equipment operation status can be detected rapidly. The tester can be installed for detection with equipment operation and without any effect to the equipment operation. This will help the workers to make evaluation timely for the switchgear cabinet operation status, and thus greatly improve the equipment operation reliability, safety and effectiveness.

The Portable PD tester consists of main tester, PD testing software, composite TEV sensors, ultrasonic sensors, high-frequency current transformer, ultrahigh frequency sensor and connecting cables.

TEV Partial Discharge Detection Equipment

Portable PD tester

Main Tester Panel

hz9003c Partial Discharge Detection Equipment

Portable PD tester main tester front panel

The front panel of the PD tester main computer is divided with several function areas, according to the above number indications,

1.Wave display

2.F1- F5 Menu Buttons

3.Power indicator

4.MEAS: measurement menu

5.AUTORANGE: Auto

6.MENU OFF: Menu off

7.MENU: Menu button

8.AUTO: Auto setting button

9.RUN/STOP: On/Off

10.Direction Key

11.TRIG: Trig menu

12.LEVEL: Adjust trigger level

13.TIME/DIV: Time base

14.POSITION: Adjust level trigger position

15.HORI: Level menu

16.VERTICAL: Adjust vertical position

17.VOLTS: Voltage shift

18.Power Switch

19.REF: REF menu

20.MATH: MATH function keys

21.CH2: display CH2 menu

22.CH1: display CH1 menu

23.UTILITY: Auxiliary function

24.SAVE RECALL: Save/Recall

25.RECORDER: Multi-meter trend chart, Oscilloscope trend chart, wave recorder.

26.SCOPE/DMM: Function interface switch button, switch to the multi-meter over signal interface.

27.CURSOR: Cursor measurement

onsite testing

Huazheng Electric Inquiry_

上一篇: Lubricating Grease Cone Penetration
下一篇: 800kV AC Withstand Voltage Test Veh
同类优质产品

在线询价

X

已经是会员?点击这里 [登录] 直接获取联系方式

会员登录

X

请输入账号

请输入密码

=

请输验证码

收藏该商铺

X
该信息已收藏!
标签:
保存成功

(空格分隔,最多3个,单个标签最多10个字符)

常用:

提示

X
您的留言已提交成功!我们将在第一时间回复您~