当前位置:Huazheng Electric Manufacturing (Baoding) Co., Ltd>>Transformer Oil Tester>>Oil Viscosity Tester>> ASTM D445 ASTM D2270 Kinematic Viscometer And Viscosity Index Tester

ASTM D445 ASTM D2270 Kinematic Viscometer And Viscosity Index Tester

产品二维码
参  考  价:面议
具体成交价以合同协议为准
  • 产品型号:
  • 品牌:
  • 产品类别:磨床
  • 所在地:
  • 信息完整度:
  • 样本:
  • 更新时间:2026-03-20 16:48:51
  • 浏览次数:
收藏
举报

联系我时,请告知来自 亚洲制造网

Huazheng Electric Manufacturing (Baoding) Co., Ltd

其他

  • 经营模式:其他
  • 商铺产品:831条
  • 所在地区:
  • 注册时间:2026-03-20
  • 最近登录:2026-03-20
  • 联系人:Julia
  • 电    话:
产品简介

HZYN-2400 ASTM D445 ASTM D2270 Kinematic Viscometer and Viscosity Index Tester I. Test Method Outline 1. Fix the viscometer which is filled well with sample on the viscometer clip cover and adjust it to vertical situation. 2. Adjust the constant temperature bath to be at specified temperature, dip the...

详情介绍

ASTM D445 ASTM D2270 Kinematic Viscometer and Viscosity Index Tester


I. Test Method Outline

1. Fix the viscometer which is filled well with sample on the viscometer clip cover and adjust it to vertical situation.

2. Adjust the constant temperature bath to be at specified temperature, dip the viscometer into the bath to be preheated (refer to the standard for preheating time). The test temperature must be kept constant within ±0.1℃ . When fix the position, the expansion part 2 of capillary viscometer must be dipped for half part.

3. Fix the thermometer. You need make the mercury ball position near to the level of capillary middle point, and make the thermometer scale which will test temperature at 10mm above the bath. When using the fully immersed type thermometer, please refer to the required calculation formula in standard to calculate the correction number.

4. Use the rubber tube covered on capillary viscometer body 1 port to inject the sample into expansion part 3, make the sample liquid level a little higher than the marking line a, and pay attention not to make bubble or gap generated on the liquid levels of capillary and expansion part 3.

5. At this time observe the flowing condition of sample in the tube body. Start the stopwatch when liquid level exactly reach marking line a, and stop it when liquid level exactly reaches marking line b.

astm d2270 D 2270 Kinematic Viscometer

1 .6-tube body; 2 .3 .5-expansion part; 4-capillary; a 、b-marking lines


6. The flowing time recorded by stopwatch needs to be repeatedly tested at least four times. The difference between every flowing time and its arithmetic mean value needs to meet the following requirements: no more than ±0.5% of the mean value at testing temperature of 100-15℃; no mare than ±1.5% at 15~ -30℃; no more than ±2.5% at lower than -30℃ . Then take the arithmetic mean value of flowing time for no less than 3 times to be the average flowing time of sample.


II. Main Technical Parameters

Temperature control range: continuously adjustable 20℃-100℃

Temperature control precision: ±0.1℃

Input power: 2000W

Power supply: 220V±10%, 50Hz

Size: 635×380×525mm, 4 holes

Huazheng customer visit

Huazheng CE Certification

Huazheng Customer feedback

Enquiry

上一篇: Automatic AC Motor Comprehensive Tes
下一篇: HZTL-1B Oil Ferromagnetic Abrasive I
同类优质产品

在线询价

X

已经是会员?点击这里 [登录] 直接获取联系方式

会员登录

X

请输入账号

请输入密码

=

请输验证码

收藏该商铺

X
该信息已收藏!
标签:
保存成功

(空格分隔,最多3个,单个标签最多10个字符)

常用:

提示

X
您的留言已提交成功!我们将在第一时间回复您~