当前位置:Huazheng Electric Manufacturing (Baoding) Co., Ltd>>High Voltage Tester>>DC Hipot Tester>> 120kV 5mA HV DC Hipot Tester

120kV 5mA HV DC Hipot Tester

产品二维码
参  考  价:面议
具体成交价以合同协议为准
  • 产品型号:
  • 品牌:
  • 产品类别:接近开关
  • 所在地:
  • 信息完整度:
  • 样本:
  • 更新时间:2026-03-20 14:42:13
  • 浏览次数:
收藏
举报

联系我时,请告知来自 亚洲制造网

Huazheng Electric Manufacturing (Baoding) Co., Ltd

其他

  • 经营模式:其他
  • 商铺产品:831条
  • 所在地区:
  • 注册时间:2026-03-20
  • 最近登录:2026-03-20
  • 联系人:Julia
  • 电    话:
产品简介

120kV 5mA HV DC Hipot Tester Product Description 120kV 5mA HV DC Hipot Tester application: The HV dc pulse generator maily apply to test the high voltage of l ightning arrester of zinc oxide, m agnetic blow lightning arrester, power cable, generator, transformer, switch equipment s and so on ....

详情介绍

120kV 5mA HV DC Hipot Tester

HZZGF 120kV 5mA HV DC Hipot Tester Application:

The HV dc hipot tester mainly apply to the high voltage of lightning arrester of zinc oxide, magnetic blow lightning arrester, power cable, generator, transformer, switch equipments and so on.

120kv DC Hipot Tester (1)

120kv DC Hipot Tester (2)

120kv DC Hipot Tester (5)

120kv DC Hipot Tester (4)

HZZGF 120kV DC Hipot Tester

120kV 5mA HV DC Hipot Tester Parameter:

1. power: AC220V+10%, 50Hz+1%

2. Output voltage indicator accuracy:<>

3. Output current indicator accuracy:<>

4. Ripple contain factor:<>

5. 0.75 times output voltage indicator accuracy:<1%, can="" be="">




rating output DC voltage(kV)

rating output DC current(mA)

rating output power(W)

doubler reticfier case height(m)

weight(kg)

HZ-60

60

2

120

0.5

16

60

5

300

0.5

60

10

600

0.5

HZ-120

120

2

240

0.8

20

120

5

600

0.8

120

10

1200

0.8

HZ-200

200

2

400

1.2

26

200

5

1000

1.2

200

10

2000

1.2

HZ-300

300

2

600

1.7

31

300

5

1500

1.7

300

10

3000

1.7

dc hipot tester

Certifications

dc hipot tester.png

FAQ

No.

Questions

Answer

1

What are the considerations when using the DC Hipot tester?

Do not overload operation, not too fast lift pressure, continuous use time should not exceed 30 minutes.

2

How does the DC Hipot tester connect with different subjects?

1. When measuring the cable, the current limiting resistance is connected to the u-fork high voltage line. 2. When measuring lightning arrester, use microammeter to connect the cylinder high pressure line.

3

What information does the customer need to know about the DC Hipot tester?

If the subject is a cable, it needs to know the voltage level to determine the voltage and the cable length to determine the current. If the test product is a generator, you need to know the voltage level and capacity to confirm. Example: for a general 35kv cable, the length of 600m can be recommended for 3mA/120kv.

4

Can the DC Hipot tester not connect the item to be tested and only use the control box and the pressure cylinder to raise the pressure?

Yes, but the ground wire must be well grounded. Do not try the grounding or radiator in the home. It is easy to burn the machine. Also, the top of the double pressure cylinder is screwed with a nut, do not connect the micro-ammeter. It is best to try it on site or in a laboratory where there is a really good grounding.

5

Is the microammeter of DC Hipot tester showing high voltage side current? What current does the meter on the control box show?

Both currents are high voltage side currents, and the microammeter is used to monitor whether the current in the control box is normal. If there is no significant difference, it means normal. In general, the current value of the microammeter is different from that of the control box because of the interference of stray current with strong interference. But it is normal that the difference will not be large.

6

What happens if the test product fails?

The test data is not accurate, or the voltage may not rise, or even burn the instrument. Because the field voltage is too high, it is easy to burn out the DC Hipot tester if there is bad grounding or wrong operation

Related suggestion products

dc hipot tester

Huazheng Electric factory

Huazheng company show

Do you want to get more information? Click "Send" now!

dc hipot tester

上一篇: HZKM-4 Four-Ball Friction And Wear T
下一篇: HZDP-40kV Hi Pot Test Equipment VLF
同类优质产品

在线询价

X

已经是会员?点击这里 [登录] 直接获取联系方式

会员登录

X

请输入账号

请输入密码

=

请输验证码

收藏该商铺

X
该信息已收藏!
标签:
保存成功

(空格分隔,最多3个,单个标签最多10个字符)

常用:

提示

X
您的留言已提交成功!我们将在第一时间回复您~