HZ-1041 Three Phase Multifunction Electrical Energy Meter Test Bench
Technical Standards And Regulations
This device complies with the requirements of the following national and industrial standards and related metrological verification regulations :
JJG597-2005 "Verification Regulations for AC Energy Meter Verification Device"
DL460-1992 "Verification Regulations for Electric Energy Meter Verification Device"
GB/T11150-2001 "Electric Energy Meter Inspection Device"
JJG596-2012 "Verification Regulations for Electronic Energy Meters"
JJG307-2006 "Verification Regulations for AC Energy Meters"
DL/T585-1995 "Technical Conditions for Electronic Standard Electric Energy Meter"
Technical Conditions
General Conditions of Use
environmental conditions
Operating environment temperature: 23°C±1°C; Operating ambient humidity: 40%~60%R.H.;
power supply
Single phase: AC220V±10%; Frequency: 50±2.5Hz
technical indicators
2.1 Device accuracy grade: 0.1/ 0.05 grade
2.2 Output voltage:
Range: 3×57.7V/100V/230V/380V;
Adjustment range: 0~120%
Adjustment fineness: better than 0.01%
Output stability: ≤0.05%/3 minutes
Output distortion: ≤0.5%
Output capacity: 20VA/epitope
Load characteristics: resistive, inductive and capacitive
Capacitive load: less than 0.47uF/epitope
Harmonic output: 2~21 harmonics, content ≤40 % ;
2.3 Output current:
Range: 10mA, 0.1A, 0.25A, 1A, 2.5A, 5A, 10A, 25A, 50A, 100A
Adjustment range: 0~120%, maximum output current: 120A
Adjustment fineness: better than 0.01%
Output stability: ≤0.05%/3 minutes
Output distortion: ≤0.5%
Maximum output capacity: 250VA
Load characteristics: resistive, inductive
Starting current output: 1 mA ( minimum), accuracy: ≤5%
Harmonic output:
2~21 harmonics, content ≤40 % ;
Even harmonics (wave group control);
Odd harmonics (SCR waveform);
2.4 Output power:
Stability: ≤0.5%/2 minutes, starting power: accuracy ≤2%;
2. 5 Output phase:
Adjustment range: 0~359.99°, adjustment fineness: 0.01°
2. 6 Output frequency:
Adjustment range: 45~65Hz, adjustment fineness: better than 0.01 Hz
2.7 Device configuration:
Standard energy meter configuration:
Three-phase high-precision standard electric energy meter, accuracy grade: 0.05 grade
Current input range: 10mA~120A; Voltage input range: 40~480V
Number of hanging watches: 16, 32 watch positions
Input and output interface:
Each epitope provides a pulse signal compatible input interface;
Each meter is equipped with a multi-channel pulse selector, providing forward and reverse active and reactive power, demand period signal, period switching signal, and clock signal input port;
Each table provides 1 RS-485 communication port
Monitoring Instruments: Readout from Standard Meters
Error handling system:
Configure independent error handlers for each epitope
Error display digits: 6 digits
Pulse miswiring input protection
High precision clock tester: accuracy: 2×10 -7 /S;
Mechanical structure
The table body adopts an all-in-one all-aluminum structure; (1 16-position hanging table rack)
The hanging watch frame is made of aluminum alloy material, and the hanging watch method adopts aluminum alloy plug-in watch holder; )
The table top is made of fireproof and heatproof material, covered with insulating mat;
other:,
The device is equipped with a current terminal for convenient verification
Device configuration high current short wiring
One set of RS-485 lines and one set of multi-function pulse lines are configured for each epitope of the device
The device is equipped with an emergency stop switch
Operation mode: It can be operated by console keyboard or PC
Multi Function Test Items
GPS time synchronization: You can use the 485 broadcast command to provide time, and you can also use the 485 setting command to write the time.
Daily timing error test: It can simultaneously measure the accuracy of second pulse output by multi-function electric energy meters with multiple gauges, and can optionally automatically convert it to daily timing error for display.
Time-period switching error test: For multi-function electric energy meters that output time-period switching signals, the time-period switching error test can be performed, and for multi-function electric energy meters without output switching signals, qualitative time-period switching results can be given according to communication, and also Time synchronization and timing operations can be performed on the multi-function electric energy meter through the communication interface.
485 port communication function: Through the 485 communication port, it is possible to perform operations such as memory power check and parameter setting on the multi-function electric energy meter with a communication port.
Demand indication value error test: The device can use the standard electric energy meter method or standard power method to test the demand indication value error of the multi-function electric energy meter. The standard electric energy method is used to test the electric energy meter with the output demand period signal, and the standard power method is used to test the electric energy meter without the quantity periodic output signal. The average power calculation method during the test can be the slip method or the average power method.
Demand periodic error test: When the standard power meter method is used to measure the demand indication error, the pulses sent by the standard crystal oscillator within two (interval type) or multiple (slip type) periodic signal intervals of the tested meter are counted by the error meter When the standard electric energy meter method is used to measure the error of the demand indication value, it is timed by the internal timer of the error meter.
Combination error test of electric energy meter: change the clock in the meter under test through the RS485 interface, complete the operation of each tariff segment in a relatively short period of time, and calculate the combined error by comparing the total meter and the change amount of each tariff meter . The mechanical scale allows manual input of start and end indications, and can compare the difference between the mechanical scale and the memory.