您好,欢迎来到亚洲制造网!请 |免费注册

产品展厅本站服务收藏该商铺

Huazheng Electric Manufacturing (Baoding) Co.
Ltd

免费会员
手机逛
Huazheng Electric Manufacturing (Baoding) Co.
Ltd
当前位置:Huazheng Electric Manufacturing (Baoding) Co., Ltd>>Transformer Tester>>CT PT Analyzer>> HZCT-100B CT PT Tester Current Transformer Test Equipment

HZCT-100B CT PT Tester Current Transformer Test Equipment

产品二维码
参  考  价:面议
具体成交价以合同协议为准
  • 产品型号:
  • 品牌:
  • 产品类别:水准仪
  • 所在地:
  • 信息完整度:
  • 样本:
  • 更新时间:2026-03-20 19:27:57
  • 浏览次数:1
收藏
举报

联系我时,请告知来自 亚洲制造网

Huazheng Electric Manufacturing (Baoding) Co., Ltd

其他

  • 经营模式:其他
  • 商铺产品:831条
  • 所在地区:
  • 注册时间:2026-03-20
  • 最近登录:2026-03-20
  • 联系人:Julia
  • 电    话:
产品简介

HZCT-100B CT PT Tester Current Transformer Test Equipment HZCT-100B Series Transformer Tester is new product created after widely adopt customers’advices and deep theoretical study. It is based on the automatic FA Series Transformer Tester General which is produced by our company that is widely...

详情介绍

HZCT-100B CT PT Tester Current Transformer Test Equipment


1 Current Transformer Test Equipment Characteristics

★ Full-featured, not only satisfy the test requirements of various CTs (include TP class), such as the excitation characteristics (i.e., volt-ampere characteristics), ratio, polarity, secondary winding resistance, secondary burden, ratio error and phase displacement, but can also be used for the tests of various PTs, including excitation characteristics of the electromagnetic unit, ratio, polarity, secondary winding resistance, ratio error and phase displacement.

★ Automatically give CT, VT parameters, including knee point voltage / current, 10% error curve, the accuracy limit factor (ALF), instrument security factor (FS), the second time constant (Ts), remanence coefficient (Kr), saturated and unsaturated inductance etc.

★ Test meet IEC60044 GB1208 (-1) GB16847 (IEC60044-6) became etc all kinds of transformer standards, and in accordance with the transformer types and levels of automatic choose which standard test

★ Based on advanced principle of low-frequency test method that can meet the CT test on knee voltage up to 30KV.

★ Friendly interface beautiful, all Chinese graphic interface

★ The instrument can store 2000 groups of test data that won’t be lost when power off. After test ended, the data can be coped to PC by USB disk for analysis and being transformed into WORD report.

★ Test is simple and convenient, one-click can complete tests of CT secondary resistance, excitation, ratio and olarity.

★ Easy to carry, because the weight is less than 9Kg.

ct pt analyzer

2 Current Transformer Test Equipment Technical Parameter


HZCT-100B

Usage

Class P/TP CT & VT

Output

0~100Vrms,12Arms,36A(peak value)

Voltage measurement accuracy

±0.2%

CT Ratio

Range

1~10000

accuracy

±0.2%

PT Ratio

Range

1~10000

accuracy

±0.2%

Phase

Range

±5min

accuracy

0.5min

DC resistance

Range

0~300Ω

accuracy

2%±2mΩ

Burden

Range

0~300VA

accuracy

2%±0.2VA

Power supply

AC220V±10%,50Hz

Environmental Conditions

  Operating temperature :-10οC~50οC,Humidity :≤90%

Weight and Dimensions

Dimensions:340 mm×300 mm×150mm,Weight<9kg

HZCT-100B_02

HZCT-100B_04

HZCT-100B_05

HZCT-100B_01

HZCT-100B_03

Current transformer test equipment




CT PT Analyzer

onsite testing

上一篇: HZSM-701 Intelligent Accuracy SF6 Mi
下一篇: Huazheng Electric HVAC Frequency Ser