当前位置:Huazheng Electric Manufacturing (Baoding) Co., Ltd>>Switchgear>> KYN28-12 Distribution Board High Voltage Metal Clad Enclose Electrical Industrial Switchgear

KYN28-12 Distribution Board High Voltage Metal Clad Enclose Electrical Industrial Switchgear

产品二维码
参  考  价:面议
具体成交价以合同协议为准
  • 产品型号:
  • 品牌:
  • 产品类别:其他
  • 所在地:
  • 信息完整度:
  • 样本:
  • 更新时间:2026-03-20 11:55:14
  • 浏览次数:
收藏
举报

联系我时,请告知来自 亚洲制造网

Huazheng Electric Manufacturing (Baoding) Co., Ltd

其他

  • 经营模式:其他
  • 商铺产品:831条
  • 所在地区:
  • 注册时间:2026-03-20
  • 最近登录:2026-03-20
  • 联系人:Julia
  • 电    话:
产品简介

KYN28-12 Distribution Board High Voltage Metal Clad Enclose Electrical Industrial Switchgear KYN28-12 armored metal-enclosed switchgear (hereinafter referred to as KYN28-12 switchgear) is suitable for three-phase AC 50Hz (60Hz), 7.2~12kV single busbar and single busbar segmented power system, with...

详情介绍

KYN28-12 Distribution Board High Voltage Metal Clad Enclose Electrical Industrial Switchgear

KYN28-12 armored metal-enclosed switchgear (hereinafter referred to as KYN28-12 switchgear) is suitable for three-phase AC 50Hz (60Hz), 7.2~12kV single busbar and single busbar segmented power system, with "five-proof" function. The removable part of the switchgear can be equipped with components such as vacuum circuit breakers and vacuum contactors.

KYN28-12 switchgear meets IEC298, GB3906, DL404 and other standards.

The degree of protection of the switchgear cabinet is IP4X. When the breaker door is opened and the handcart is removed, the degree of protection is IP2X.

All relevant IEC specifications and national or local safety guidelines are to be observed during installation and operation of the system.

kyn28a-12 KYN28-03 kyn2812 metal enclosed switchgear.jpg

Technical parameter

Rated voltage

kV

12(Can be customized according to local national standards)

Rated insulation level

1min power frequency withstand voltage (effective value)

kV

42

Lightning impulse withstand voltage (peak)

kV

75

Rated frequency

Hz

50

Main busbar rated current

A

630,1250,1600,2000,2500,3150,4000

Branch busbar rated current

A

630,1250,1600,2000,2500,3150,4000*

4 second thermal stable current (RMS)

kA

16,20,25,31.5,40**

Rated dynamic steady current (peak)***

kA

40,50,63,80,100

*Equipped with ventilation device **40 kA is 3 seconds The short-circuit capacity of the instrument transformer should be considered separately