HZ-A10 Power Cable Fault Detection Equipment
System Configuration:
Cable Fault Test System | Name | Model | quantity | Remark |
Cable fault location unit | HZ-A10 | 1 | Windows Operating System 12 inch industrial grade all-in-one machine control | |
Pointing instrument | HZ-B | 1 | ||
High frequency & high voltage power supply | HZ-G35A | 1 |
HZ-A10 Cable fault location unit
I. Overview
The equipment is used for rough measurement of cable fault distance. Test the fault distance of the full length of the faulty cable, low-resistance faults, and high-resistance faults
II. Technical Parameter
Display mode: 12.1-inch industrial-grade LCD screen (windows 7)
Test distance: No less than 60km
Operation mode: Touch mouse operation
Test method: low voltage pulse method, flash current method, direct flash current method
Storage space: fixed 8G
Min. Test distance (non-detection area): 0.5m or without
Locating error: ±0.2m
Resolution: V/fm,V is transmitting velocity m/μs;software cursor is 0.15m
Test error: system error is less than ±1%
Sampling frequency: 6.25MHz,12.5MHz,25MHz,50MHz,100MHz (Adaptive pulse width).
Pulse width: 50ns, 80 ns, 100ns, 200 ns, 1μs, 2μs, 5μs, 10μs (software automatic matching);
Standby time: continuous working 4 hours
The host weight:7kg
Size:180mm×300mm×400mm
HZ-B Cable Fault Pinpointer
Sensor dynamic range: sound channel >104dB.
Impact discharge sound amplification factor >90dB, impact discharge volume limit 84dB(A).
LCD: high brightness color screen, 320 x 240 pixels suitable for outdoor.
Continuous working time on site: alkaline replaceable battery, convenient for site use
HZ-G35A Integrated High Frequency High Voltage Power Supply
Chapter 1. Performance characteristics
1. Integrated design, built-in capacitor, simple wiring.
2.Touch screen, simple setting and operation, intuitive and convenient display.
3. With voltage regulation, automatic voltage stabilization and automatic protection functions.
4. The output high voltage has the function of single pulse and continuous pulse.
5. The output high voltage has a DC output, which can work with an external ball gap, and has a variety of applications.
6. The software controls vacuum impulse ignition and discharge, self-adaptive discharge and pulse period.
7. With emergency stop button, automatic discharge function, safe and reliable.
8. The continuous working time is not less than 6 hours, meeting the longest working time of cable fault test.
9. Engineering chassis design, compact structure, small size, light weight, easy to carry by one person.
Chapter 2. Technical parameters
1. Output mode: pulse output, DC output
2. Output voltage: negative voltage, 0~-35kv continuously adjustable
3. Working current: ≤40mA
4. Working mode: single pulse, continuous pulse, DC output
5. Built-in capacitance: 2.8uF/35kv
6. Discharge energy: ≤1715J
7. Pulse period: 3s~8s adaptive
8. Automatic discharge: automatic discharge after shutdown
9. Working power supply: power frequency 220V±10%
10. Display screen: 800×480 resolution touch screen
11. Working temperature: -10℃~40℃
12. Working humidity: ≤80%
13. Altitude: ≤1000m
14. Dimensions: 478(L)*370(W)*448(H) mm
15. Weight: ≤28kg