HZGC-1212Q gas chromatograph has the characteristics of reliable performance, compact structure, strong scalability, simple operation, convenient maintenance, for online analysis of university laboratory, petrochemical, environmental monitoring and other application needs, can be flexibly customized application scheme, provide customers with excellent analysis function and performance, It's a truly high-performance gas chromatograph.
number | name | specifications and models | Quantity/ unit |
1 | HZGC-1212Q Gas chromatograph | Gas chromatography mainframe | 1 set |
FID detector | 1 set | ||
Shunt/non-shunt capillary column injection port | 1 set | ||
2 | chromatographic column | Homebred analytical column | 1 piece |
3 | workstation | Anti control workstation | 1 set |
4 | spare part | Including installation tools, consumables | 1 set |
5 | air supply | Nitrogen cylinder 99.999% or more | Customer should bring along their own |
hydrogen generator | 1 set | ||
Air generator | 1 set | ||
6 | Computer | Lenovo Business Computer | Customer should bring along their own |
Note:
1. Attached accessories are free of charge, and accessories are provided for a long time
2. Help users establish analysis methods.
Product feature
1.Advanced injection port design
(1)The injection system can be equipped with single filling column system, single capillary column system, packed capillary sample injection system and double capillary sample injection system.
(2)The instrument is suitable for a variety of sampling injection methods, such as headspace sampling injection, thermal analytical sampling injection, etc., easily competent for the analysis of various samples.
2.Super large volume column box design
(1)300×280×180(mm) large volume column box, can easily achieve four valves and five pillars, and support the installation of five valves and seven pillars.
(2)The highest heating rate is 80℃/min, the highest temperature control is 450℃, and the temperature control accuracy is ±0.1℃.
3.Unique logarithmic amplifier technology
(1)Using logarithmic amplifier, for weak signals get high gain amplification, for strong signals automatically reduce the gain, to avoid saturation.
(2)Interference reduction, high sensitivity, good linearity, wide range.
4.Powerful detector expansion function
(1)The detector and its control components are designed by combination of units, plug and play, independent configuration.
(2)Support multiple detectors (TCD, FID, ECD, FPD, NPD, etc.).
(3)Modular configuration based on user analysis requirements, convenient maintenance.
5.Super efficient back opening door design
(1)Equipped with intelligent back opening door temperature control system, to ensure the stability of the temperature of the column chamber in any area, can realize the real sense of near room temperature operation.
(2)It can carry out 16 step of temperature programmed Heating operation, with excellent column box performance, high temperature control accuracy and fast temperature rise and drop speed.














所有评论仅代表网友意见,与本站立场无关。