5kV AC DC IR GR Hi Pot Leakage Current Tester Electrical Safety Compliance Analyzer

Brief Introduction
The CS267X series products of Electrical Safety Compliance Analyzer, based on introducing and digesting the advanced withstand voltage testers worldwide, combine with a large number of practical usage cases from Chinese users to enhance and improve.
CS2670A, CS2670A-1, CS2670AX, CS2670Y, CS2671AX, CS2671BX, CS2671TX, CS2672BX, CS2672CX, CS2672DX, CS2673X,
CS2674AX type, etc Electrical Safety Compliance Analyzers are full digital model Electrical Safety Compliance Analyzer series products latterly developed by our factory. Both the testing voltage and the leakage current dwell time are displayed in digital, which the technique is the first applied in China. Based on the original products, its performance is further improved. The leakage current can be continuously and optionally set from 0.1 mA to 100 mA according to the different security standards and the different requirements of users. For the time testing, the disadvantage, which the indication difference of the original product is a few greater, is improved, with the digital count-down-display, the precision of dwell time is increased to above ±1%, and the testing range is improved to 99 s. Its
function is richer and more practical, and the actual leakage current
values of the measured object can be reflected through the leakage current display to achieve which products its withstand voltage grade is better compared with the different lots of the similar products or different manufacturers‟ products, which the security performance of your products can be guaranteed to have no fault. At the same time, the digital displayed leakage current can be used to simultaneously display its function, and extended to measure the reverse voltage and reverse leakage current of the high voltage silicon rectifier stack, the reserve voltage and reserve leakage current of the high withstand voltage tube of a dynatron. It is a domestic leading Electrical Safety Compliance Analyzer compared from technique performance to quality, reliability.
Working theory
Electrical Safety Compliance Analyzer is made up of high voltage rise circuit, leakage current detecting circuit and indicating meter. High voltage rise circuit can calibrate and output the required test voltage; Leakage current is capable of setting breakdown(protection) current; Indicating meter can directly read out the test voltage value and leakage current value( or set breakdown current value). DUT reaches the regulated time under the effect of test voltage, and instrument cuts off test voltage automatically or manually, once breakdown appears and leakage current goes beyond the set breakdown current, instrument can automatically cut off the output voltage and alert to confirm whether DUT can bear the insulation intensity test.
Standards:
IEC60065: Safety for audio, video and similar electronic apparatus IEC60204-1: Safety of machinery
IEC60335-1: Safety of household and similar electrical appliances IEC60598-1: Safety of lighting equipment
IEC60601-1: Safety of medical electrical equipment IEC60950: Safety of information technology equipment
IEC61010-1: Safety for electrical equipment for measurement, control and laboratory use
IEC61131-2: Safety for automatons
Technical parameter
1.Model List
MODEL | |
CS2670A | ACW: 5kV, 20mA |
CS2670A-1 | ACW: 5kV, 20mA |
CS2670AX | ACW: 5kV, 20mA |
CS2670Y | ACW: 5kV, 20mA |
CS2671AX | ACW: 10kV, 20mA; DCW: 10kV, 10mA |
CS2671BX | ACW: 10kV, 50mA; DCW: 10kV, 20mA |
CS2671TX | ACW: 10kV, 100mA |
CS2672BX | ACW: 5kV, 100mA |
CS2672CX | ACW: 5kV, 100mA DCW: 5kV, 20mA |
CS2672DX | ACW: 5kV, 20mA DCW: 5kV, 10mA |
CS2673X | ACW: 5kV, 200mA |
2.Technical parameters
①CS2670A/CS2670A-1/CS2670AX
CS2670A | CS2670A-1 | CS2670AX | CS2670Y | ||||
ACW | Output voltage | (0.00~5.00)kV | |||||
Max. output power | 100VA(5.000kV/20mA) | ||||||
Max. current | 20mA | ||||||
Current range | 2mA、20mA | ||||||
Output waveform | sine wave | ||||||
Waveform distortion | ≤5%(unload or pure resistance load) | ||||||
Test time | 0.0s~999s 0=continue | ||||||
Volt meter | Range | 0.00kV~5.00kV | |||||
Accuracy | ±(5%+5 word ) | ||||||
resolution | 10V | ||||||
Displayed value | RMS | ||||||
Ammeter | Range | AC | 0.100mA ~ 20.00mA | ||||
resolution | AC | 2mA:1uA, 20mA:10uA | |||||
Accuracy | ±(5%+5 words ) | ||||||
Timer | Range | 0.0s~999s | |||||
Min. resolution | 0.1s | ||||||
Accuracy | ±(1%+50ms) | ||||||
PLC interface | no | no | yes | no | |||
Remote interface | yes | ||||||
②CS2671AX/CS2671BX/CS2671TX
CS2671AX | CS2671BX | CS2671TX | |||||
AC W | Output voltage | (0.00~10.00)kV | |||||
Max.output power | 100VA | 500VA | 1000VA | ||||
Max. current | 20mA | 50mA | 100mA | ||||
Current range | 2mA、20mA | 2mA、20mA、50mA | 2mA、20mA、100mA | ||||
Output waveform | sine wave | ||||||
Waveform distortion | ≤5% | ||||||
Test time | 0.0s~999s 0.0= continue | ||||||
D CW | Output voltage | (0.00~10.00)kV | |||||
Max. output power | 100VA | 500VA | -------------------- | ||||
Max. current | 10mA | 20mA | -------------------- | ||||
Current range | 2mA、10mA | 2mA、20mA | -------------------- | ||||
Ripple factor | ≤5% | ||||||
Test time | 0.0s~999s 0= continue | ||||||
Volt meter | Range | (0.00~10.00)kV | |||||
Accuracy | ±(5%+5 words ) | ||||||
resolution | 10V | ||||||
Displayed value | RMS | ||||||
Ammeter | Measure Range | AC | 0.100mA ~ 20.00mA | 0.100mA ~ 50.00mA | 0.100 ~ 100.0mA | ||
DC | 0.100mA ~ 10.00mA | 0.100mA ~ 20.00mA | -------------------- | ||||
Resolution | AC | 2mA:1uA,20mA:10uA,50mA(100mA):0.1mA | |||||
Accuracy | ±(5%+5 words ) | ||||||
Timer | Range | 0.0s~999s | |||||
Min. resolution | 0.1s | ||||||
Accuracy | ±(1%+50ms) | ||||||
PLC interface | no | no | Yes | ||||
Remote interface | yes | ||||||
③CS2672BX/CS2672CX/CS2672DX
A C W | Output voltage | (0.00~5.00)kV | ||||
Maxoutput power | 500VA | 100VA | ||||
Max. current | 100mA | 20mA | ||||
Current range | 2mA、20mA、100mA | 2mA、20mA | ||||
Output waveform | sine wave | |||||
Waveform distortion | ≤5% | |||||
Test time | 0.0s~999s 0.0= continue | |||||
D C W | Output voltage | ----------------------------- | (0.00~5.00)kV | (0.00~5.00)kV | ||
Max. output power | ----------------------------- | 100VA | 50VA | |||
Max. current | ----------------------------- | 20mA | 10mA | |||
Current range | ----------------------------- | 2mA、20mA | 2mA、10mA | |||
Ripple factor | ----------------------------- | ≤5% | ||||
Test time | ----------------------------- | 0.0s~999s 0= continue | ||||
Volt meter | Range | (0.00~50.00)kV | ||||
Accuracy | ±(5%+5 words ) | |||||
resolution | 10V | |||||
Displayed value | RMS | |||||
Ammeter | Measure Range | AC | 0.100mA ~ 100.0mA | 0.100mA ~ 100.0mA | 0.100mA~20.00mA | |
DC | ---------------------------- | 0.100mA ~ 20.00mA | 0.100mA~10.00mA | |||
Resolution | 2mA:1uA, 20mA:10uA, 50mA:0.1mA | |||||
Accuracy | ±(5%+5 words ) | |||||
Timer | Range | 0.0s~999s | ||||
Min. resolution | 0.1s | |||||
Accuracy | ±(1%+50ms) | |||||
PLC interface | no | no | Yes | |||
Remote interface | yes | |||||