Section 1 main features
1, Meet all the test requirements. Can be a variety of relay and protection device of the traditional test, also can carry out various tests on all kinds of modern computer protection, especially for transformer differential protection and automatic device, the test is more convenient and perfect
1) FDJB344AE has a standard four phase voltage, three-phase current output, voltage 125V/ phase, current 40A/ phase. Parallel three-phase current up to 120A
2, A variety of technical indicators fully meet the Ministry issued by the Ministry of power DL/T624-1997 "relay protection microcomputer test device technical conditions" standard.
3, Stand-alone operation, built-in high-performance industrial computer, clocked at 1.7GHz, memory 2G, hard disk 16G, running Windows XP operating system.
4, the domestic industry first imported stainless steel wire drawing panel, acrylic digital keyboard, and a touch mouse, overcome the trackball mouse operation is not flexible and easily damaged weaknesses, and use 8.4 inch TFT LCD, resolution 800 * 600, the single overall operation is convenient, durable.
5, The main control board uses DSP+FPGA structure, 16 DAC output, a high density of Jiboke sine wave 2000 points per cycle, greatly improved the quality of waveform improves the test accuracy.
6, The use of high fidelity linear amplifier amplifier, both to ensure the accuracy of small current, but also to ensure the stability of large current.
7, The use of USB interface and PC communication directly, without any transfer line, easy to use.
8, Can be connected to the notebook computer. Notebook computer and industrial computer use the same set of software, no need to re learn the operation method.
9, With an independent dedicated DC auxiliary voltage source output, the output voltage of 110V (1A), 220V (0.6A). To provide for the use of DC power supply of the relay or protective device.
10, With the software self calibration function, to avoid the need to open the chassis by adjusting the potentiometer to calibrate the accuracy, thereby greatly improving the accuracy of the stability.
Section second technical parameters
FDJB344AE technical parameters
1, Alternating current source:
Phase current output (RMS): 0--40A/ phase accuracy: 0.5%
Three phase parallel output (RMS):0--120A/ phase parallel output Phase current allows for a long time working value (RMS):10A
Maximum output power per phase: 420VA
The maximum output power of three-phase shunt current: 900VA
Three and the maximum current output allows working time: 10s Frequency range: 0--1000Hz accuracy: 0.001Hz
Harmonic number: 2--20 phase: 0--360 º accuracy: 0.5 º
2, DC current source:
Current output: 0-- + 10A/ phase accuracy of 0.5% VA 300
3, AC voltage source:
Phase voltage output (RMS): 0--125V/ phase accuracy: 0.5%
Line voltage output (RMS): 0--250V
Phase voltage / line voltage output power: 75VA/100VA
Frequency range: 0--1000Hz accuracy: 0.001Hz
Harmonic number: 2--20 phase: 0--360 º accuracy: 0.5 º
4, DC voltage source:
Phase voltage output amplitude: 0-- + 150V accuracy: 0.5%
Line voltage output amplitude: 0-- + 300V
Phase voltage / line voltage output power: 90VA/180VA
5, Switch terminal:
Switch input terminals: 8 pairs
Null contact: 1--20mA, 110V internal active output
Potential reversal: 0--6VDC is low
15--250VDC is high
Switch output terminal: 4 points, breaking capacity: 110V/2A, 220V/1A.
6, Time measurement range:
Range: 1ms--9999s measurement accuracy: 1ms
7, Volume weight:
Volume: 365 (mm) x 400 (mm) x (mm) about 18Kg
8, Power: AC220V + 10% 50Hz 10A