磁力泵的注意事项

  1.防止颗粒进入
  1. To prevent the particles into

  (1)不允许有铁磁杂质、颗粒进入磁力传动器和轴承摩擦副。(2)输送易结晶或沉淀的介质后要及时冲洗(停泵后向泵腔内灌注清水,运转1min后排放干净),以保障滑动轴承的使用寿命。 (3)输送含有固体颗粒的介质时,应在泵流管入口处过滤。 (1) does not allow   any ferromagnetic impurities, particles into the magnetic actuator and the bearing friction pair. (2) The transmission medium easy to crystallize or precipitate after going to the timely processing (after the pump stopped pumping cavity infusion of water, running clean emissions after 1min) in order to protect the life of sliding bearings. (3) transport medium containing solid particles should be filtered at the entrance to the pump flow tube.

  2.防止退磁
  2. To prevent the demagnetization

  (1)磁力矩不可设计得过小。(2)应在规定温度条件下运行,严禁介质温度超标。可在磁力泵隔离套外表面装设铂电阻温度传感器检测环隙区域的温升,以便温度超报警或停机。
  (1) magnetic moment can not be designed too small. (2) should be run under the specified temperature conditions, the temperature exceeded medium is strictly prohibited. Magnetic pumps can be installed in the outer surface of isolated sets of platinum resistance temperature sensor detecting temperature annulus region in order to overrun when the temperature alarm or shut down.

  3.防止干摩擦
  3. Prevention of dry friction

  (1)严禁空转。(2)严禁介质抽空。(3)在出口阀关闭的情况下,泵连续运转时间不得超过2min,以防磁力传动器过热而失。
  (1) idling is strictly prohibited. (2) The medium is strictly prohibited for taking the time. (3) In the case of export of valve closure, pump continuous operation time of no more than 2min, to prevent overheating and loss of magnetic actuators.

版权与免责声明:
1.凡本网注明"来源:亚洲制造网"的所有作品,版权均属于兴旺宝装备总站,转载请必须注明兴旺宝装备总站。违反者本网将追究相关法律责任。
2.企业发布的公司新闻、技术文章、资料下载等内容,如涉及侵权、违规遭投诉的,一律由发布企业自行承担责任,本网有权删除内容并追溯责任。
3.本网转载并注明自其它来源的作品,目的在于传递更多信息,并不代表本网赞同其观点或证实其内容的真实性,不承担此类作品侵权行为的直接责任及连带责任。其他媒体、网站或个人从本网转载时,必须保留本网注明的作品来源,并自负版权等法律责任。 4.如涉及作品内容、版权等问题,请在作品发表之日起一周内与本网联系。