Sulfur Hexafluoride Recovery Unit SF6 Gas Recovery And Refill Equipment

No. | Indicator Name and Unit | HZSF-15-50 | |
1 | Power Supply AC | V | 380 |
2 | Rated maximum gas storage pressure(20℃) | MPa | ≥4 |
3 | Final vacuum | Pa | ≤10 |
4 | Vacuum maintenance of device | Pa | At 133 Pa pressure for 24 hours, the vacuum value increased <400 Pa |
5 | Compressor pumping rate | m3/h | Shenyang Valley Wheel 10m3/h Compressor |
6 | Vacuum pump pumping rate | m3/h | Shanghai bipolar pump 54 m3/h=15L/S |
7 | Adaptation inlet pressure of the recovery unit(20℃) | MPa | 0~0.8 |
8 | Recovery final pressure of electrical equipment(20℃) | MPa | ≤50 Kpa |
9 | Gas oil content control after recovery | μg/g | Domestic oil<10 |
10 | Annual leakage rate of the device | % | <1 |
11 | Continuous trouble-free running time of the device | h | ≥1000 |
12 | Accumulated trouble-free running time | h | ≥5000 |
13 | Noise level | dB(A) | The whole machine≤75 |
14 | Actual liquid storage capacity | KG | 50 |
15 | Refrigerated liquefaction compressor | Domestic Compressor | |
16 | Frozen storage tank | L | 50 |
17 | Gas moisture after recovery(PPM/V) | PPM/V | 60 |
18 | Gas oil after recovery(PPM/V) | PPM/V | 60 |
19 | Dry filtration mode | Vacuum heating activation regeneration | |
20 | Initial inflation pressure(pa) | pa | ≤133 |
21 | Inflation final pressure(mpa) | mpa | 0.8 |
22 | Aeration rate(m³/h) | m³/h | ≥5 |
23 | Gasification way | Automatic temperature control of electric heating | |
24 | Overall dimensions | Length * width * height | 1360×800×1300 |
25 | Vacuum gauge | Shanghai YunJie | |

















所有评论仅代表网友意见,与本站立场无关。