Digital RCD (ELCB) Tester Leakage Protection Switch Tester Battery Powered AC Voltage Test UNI-T UT585/UT586
Detailed:
1. AUTO RAMP function to test trip time and trip current;
2. 3 LED lamp for connectivity check;
3. Auto Data Hold function to display trip time for several seconds after each test;
4. Phase Switch Selection (0°and 180°) to test shortest triggering time;
5. Overload indication – “OL";
6. Environmental: no battery is required. Powered directly from testing subject (A/C 220V/50Hz);
7. Fused protection and double insulation structure for extra safety;
8. Intelligent micro-processing controller to provide high-accuracy and reliability;
9. Ergonomic design;
10. Comply with IEC 61010-1 CAT III 300V; IEC 61557-1,5; IEC 61010-2-31.
Contrast:
| Specification | Range | Best Accuracy | ||||
| Model | UT583 | UT585 | UT586 | |||
| RCD Measurement | Range Select | Rated Operating Current | Trip Time | √ | √ | √ |
| X 1/2 | 10mA/20mA/30mA/100mA/300mA/500mA | 1000mS | √ | √ | ||
| 10mA/20mA/30mA/100mA/200mA/300mA/ 500mA/1000mA | 2000mS | √ | ||||
| X 1 | 10mA/20mA/30mA/100mA/300mA/500mA | 1000mS | √ | √ | ||
| 10mA/20mA/30mA/100mA/200mA/300mA | 1000mS | √ | ||||
| 500mA/1000mA | 2000mS | √ | ||||
| X 2 | 10mA/20mA/30mA/100mA/300mA | 1000mS | √ | √ | ||
| 10mA/20mA/30mA/100mA/200mA/300mA/ 500mA | 200mS | √ | ||||
| X 5 | 10mA/20mA/30mA/100mA | 200mS | √ | √ | ||
| 10mA/20mA/30mA/100mA/200mA | 40mS | √ | ||||
| AUTO RAMP | 10mA/20mA/30mA/100mA/300mA/500mA | 300mS | √ | √ | ||
| 10mA/20mA/30mA/100mA/200mA/300mA/ 500mA/1000mA | 300mS | √ | ||||
| MANUAL RAMP | 10mA/20mA/30mA/100mA/200mA/300mA/ 500mA/1000mA | 300mS | √ | |||
| Trip Current Accuracy | ±10% | ±10% | ±10% | |||
| Trip Time Accuracy | ±(1%+3) | ±(1%+3) | ±(0.6%+4) | |||
| Trip Time Resolution | 1mS | 1mS | 1mS | |||
| Operational Voltage(Freq.) | 230V(50Hz) | ±10% | ±10% | ±10% | ||
| AC Voltage (V) (Freq.) | 60V-400V(50-60Hz) | ±(3%+5) | ±(3%+5) | ±(3%+5) | ||
| Features | ||||||
| Auto Power Off | √ | √ | √ | |||
| Low Battery Indication | √ | √ | √ | |||
| Data Hold | √ | √ | √ | |||
| LCD Backlight | √ | √ | √ | |||
| Contact Voltage Automatic Detection | √ | √ | √ | |||
| Over-Temperature Detection Instrumentation Devices | √ | √ | √ | |||
| Lock Test Function | √ | √ | ||||
| Connections Check Function | Lamps Indication | √ | √ | √ | ||
| Fuse Security | √ | √ | √ | |||
| General Characteristic | ||||||
| Power | 1.5V Alkaline Batteries (LR6) X 8 (not included) | |||||
| LCD Size | 125mm X 37mm | |||||
| Product Color | Red and Grey | |||||
| Product Net Weight | 1000g | |||||
| Product Size | 210mm X 175mm X 90mm | |||||
| Standard Accessories | Test Lead | |||||
| Standard Individual Packing | Gift Box, Tool Box, English Manual | |||||
| Standard Quantity Per Carton | 4 PCs | |||||
| Standard Carton Measurement | 510mm X 330mm X 330mm (0.056CBM Per Standard Carton) | |||||
| Standard Carton Cross Weight | 15Kg | |||||

















所有评论仅代表网友意见,与本站立场无关。