当前位置:Huazheng Electric Manufacturing (Baoding) Co., Ltd>>SF6 Gas Analyzer>> HZSF-641 SF6 Gas Discharge H2S SO2 Content Measuring Purity And Dew Point Tester

HZSF-641 SF6 Gas Discharge H2S SO2 Content Measuring Purity And Dew Point Tester

产品二维码
参  考  价:面议
具体成交价以合同协议为准
  • 产品型号:
  • 品牌:
  • 产品类别:接近开关
  • 所在地:
  • 信息完整度:
  • 样本:
  • 更新时间:2026-03-20 11:43:10
  • 浏览次数:
收藏
举报

联系我时,请告知来自 亚洲制造网

Huazheng Electric Manufacturing (Baoding) Co., Ltd

其他

  • 经营模式:其他
  • 商铺产品:831条
  • 所在地区:
  • 注册时间:2026-03-20
  • 最近登录:2026-03-20
  • 联系人:Julia
  • 电    话:
产品简介

HZSF-641 SF6 Gas Discharge H2S SO2 Content Measuring Purity And Dew Point Tester I Technical feature and parameter The SF6 comprehensive tester integrates the SF6 dew point meter, the SF6 purity meter and the SF6 decomposition product analyzer into one, and the functions that were originally realized...

详情介绍

SF6 Gas Discharge H2S SO2 Content Measuring Purity And Dew Point Tester

I Technical feature and parameter

The SF6 comprehensive tester integrates the SF6 dew point meter, the SF6 purity meter and the SF6 decomposition product analyzer into one, and the functions that were originally realized with three instruments are concentrated in one instrument. With one on-site measurement, three indicators can be tested, which greatly saves gas in the equipment. One measurement saves 2/3 gas consumption, and at the same time reduces user workload and improves work efficiency.

SF6 Gas Tester (1)

SF6 Gas Tester (2)

SF6 comprehensive tester

HZSF-641_03

1. Fast and gas-saving: After the start-up into the measurement state, the measurement time per SF6 gas dew point is about 5 minutes, and the measurement time of SF6 purity and SF6 decomposition material is about 2 minutes.

2. Self-locking joint: It adopts Germany imported self-locking joint, which is safe and reliable, and has no air leakage.

3. Data storage: With a large capacity design, up to 200 sets of test data can be stored.

4. Curve function: The large screen curve shows the dew point measurement process.

5. Clear display: LCD screen directly displays dew point, micro water (ppm), SF6 purity, SO2, H2S content ambient temperature, ambient humidity, time and date.

6. Built-in power supply: Built-in 4Ah rechargeable lithium battery, sufficient for 10 hours of continuous operation.

sf6 gas analyzer

1. Purity Measurement range 0%~99%

Measurement accuracy ±0.5%

Measurement time<2 minutes.

2. Dew point Measuring range -80 °C ~ +20 °C

Measurement accuracy ±1°C

Response time: (+20°C)

63% takes 5 seconds, 90% takes 45 seconds (-60°C~+20°C)

63% takes 10 seconds, 90% takes 240 seconds (-80 °C ~ -60 °C)

3. H2S measurement range 0~100ppm

Minimum detection amount ≤0.1ppm

Accuracy ±0.5%

Stability 0~100ppm

Repeatability ≤2%

4. SO2 measurement range 0~100ppm

Minimum detection amount ≤0.1ppm

Accuracy ±0.5%

Stability 0~100ppm

Repeatability ≤2%

5.Ambient temperature -40°C~+60°C

6. Ambient humidity 0~99% RH

7. Power supply AC 220V, Built-in rechargeable battery

8. Battery performance Charging time: 20 hours; use time is more than 10 hours.

9. Weight 5 kg

10. Size 250×150×300mm3

11. Working temperature -40 ° C ~ +80 ° C

SF6 Gas Analyser

sf6 Analyser

onsite testing

上一篇: UNI-T LM550G Laser Level Prices Gree
下一篇: HZ2822 Pilot Frequency Transmission
同类优质产品

在线询价

X

已经是会员?点击这里 [登录] 直接获取联系方式

会员登录

X

请输入账号

请输入密码

=

请输验证码

收藏该商铺

X
该信息已收藏!
标签:
保存成功

(空格分隔,最多3个,单个标签最多10个字符)

常用:

提示

X
您的留言已提交成功!我们将在第一时间回复您~