产品简介

HZ-3120A Transformer DC Resistance Tester Introduction DC resistance of the transformer will test the project of a transformer manufacturing semi-finished products,finished appearance test,installation, testing and transfer of power sector preventive trials , which can effectively find the...

详情介绍

HZ-3120A Transformer Winding DC Resistance Tester

I. Introduction


The DC resistance is the transformer’s semi-finished product, finished product test, installation, commissioning test, and electric part prevention test necessary test project,the transformer coil can effectively find the device welding, connecting parts loose, missing unit, disconnection, and other manufacturing default and other hidden danger occurred after operation.


The DC Resistance transformer to meet fast measurement requirement, we developed HZ-3120A DC Resistance Tester. The instrument is a new powerful technology, small size, light weight, high output current and other characteristics.


The device is controlled by the microcontroller, with a high degree of automation, automatic discharge functions. It is a test instrument of high precision, simple, direct way to achieve fast transformer measurement.

DC Resistance Tester 20A (2)

HZ-3120A Transformer DC Winding Resistance Tester 20A

II. Safety Measure


1. Before using this equipment you must carefully read the manual.


2. The equipment operator should have electric general knowledge


3. Avoid putting the equipment in the contact of the rain, corrosive gas, dust, high temperature, direct sunlight, and other places.


4. Severe vibration has to be avoiding for gauges.


5. Only an expert must maintain and adjust the equipment


6. After the test, the user must wait till the discharge alarm stopped before switching off the device, and plugging off the test cables.


7. To measure no-load regulating transformers, the user has to wait till the discharge instructions alarm stops before switching stalls.


8. During testing, do not move the testing clamp and cables


III. Technical Data


1. Output current:<5ma 、1a、2.5a、5a="" 、10a、20a="">


2. Resolution:0.1μΩ


3. Range:

100μΩ~1Ω (20A)

500μΩ~2Ω (10A)

1mΩ~4Ω (5A)

2mΩ~8Ω (2.5A)

5mΩ~20Ω (1A)

10Ω~20KΩ (<5ma)>


4. Accuracy:±(0.2%+2 Readings)


5. Operating temperature:0~40℃


6. Ambient humidity:≤90%RH,(non condensed)


7. size:400mm*225mm*350mm.


8. Instrument weight :13kg, wiring case:5kg.

transformer dc winding resistance test


Packing List

Name Qty
Main host 1
Testing line 1
Power line 1
User’s manual 1
Quality pass card 1
Insurance tube 2
Print Paper 1
Packing list 1
Grounding line 1
Serial port line 1
Test sample 1

HZ-3120A Transformer DC Resistance Tester.jpg

Huazheng Electric factory

Huazheng company show

Huazheng Products process

Huazheng Onsite Testing

上一篇: HZ-3110 Transformer DC Resistance Te
下一篇: HZ-3105B Transformer Winding DC Resi
同类优质产品

在线询价

X

已经是会员?点击这里 [登录] 直接获取联系方式

会员登录

X

请输入账号

请输入密码

=

请输验证码

收藏该商铺

X
该信息已收藏!
标签:
保存成功

(空格分隔,最多3个,单个标签最多10个字符)

常用:

提示

X
您的留言已提交成功!我们将在第一时间回复您~